Product
Function: | Simultaneously measure two AC voltages, current, phase between voltages, phase between currents, phase, frequency, active power, reactive power, apparent power, power factor between voltage and current |
Voltage range: | AC 0.00V~600V |
Current range: | AC 0.0mA~20.0A |
Phase range: | 0.0°~360.0° |
Power factor: | -1~+1 |
Gear: | Automatic shift |
Data storage: | 500 groups |
USB interface: | Have, can upload to computer |
Function | Measure three-phase AC voltage, current, voltage phase, current phase, voltage and current phase, frequency, phase sequence, active power, reactive power, apparent power, power factor, judging the transformer wiring group, inductive, capacitive circuit, test secondary circuit and busbar protection system,read out the phase relationship between the CTs of the differential protection groups, check the correctness of the wiring of the watt-hour meter, repair the line equipment, etc. | ||
Power | DC3.7V Ni-MH rechargeable battery | ||
Power consumption | Turn on the backlight with the maximum power consumption of 50mA, and the battery works continuously for more than 12 hours | ||
Display mode | LCD display,72×55mm | ||
Instrument size | L/W/T:187*119*48mm | ||
Voltage range | AC 0.00V~600V | Resolution:0.01V | Accuracy:±(0.5% FS) |
Current range | AC 0.0mA~20.0A | Resolution:0.1mA | Accuracy:±(0.5% FS) |
Phase range | 0.0°~360.0° | Resolution:0.1° | Accuracy:±1° |
Frequency range | 45.00Hz~65.00Hz | Resolution:0.01Hz | Accuracy:±0.5Hz |
Active power range | 0.0W~12kW | Resolution:0.1W | Accuracy:±(3%rdg+3dgt) |
Reactive power range | 0.0W~12kVAR | Resolution:0.1VAR | Accuracy:±(3%rdg+3dgt) |
Apparent power range | 0.0W~12kVA | Resolution:0.1VA | Accuracy:±(3%rdg+3dgt) |
Power factor range | -1~+1 | Resolution:0.001 | Accuracy:±0.03 |
Detection rate | About 2 second/time | ||
Data hold | Press HOLD key to hold data during test, "HOLD" symbol display | ||
Data storage | 500 groups | ||
Silicone protective sleeve | Have | ||
USB interface | USB interface, uploading data to a computer for analysis of management data | ||
Automatic shut-down | About 15 minutes after power on, the meter will automatically shut down to reduce battery consumption | ||
Backlight function | Yes, suitable for dark places and night use | ||
Voltage detection | When the battery voltage is lower than 5.2V, the battery voltage is low and the symbol indicates, prompting timely charging | ||
Instrument weight | Host:362g(Ni-MH rechargeable battery pack) | ||
Tip-shaped current clamp:180g×2 | |||
Test line:190g | |||
Voltage test line length | 1.5m | ||
Current clamp line length | 2m | ||
Working temperature and humidity | -10℃~40℃;below 80%Rh | ||
Storage temperature and humidity | -10℃~60℃;below 70%Rh | ||
Input impedence | Test voltage input impedance is:1MΩ | ||
Pressure resistance | The withstand voltage of 1000V/50Hz sine wave AC voltage between the instrument circuit and the housing lasts 1 minute | ||
Insulation | Between instrument line and housing≥100MΩ | ||
Structure | Housing insulation | ||
Suitable for safety regulations | IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,pollution level 2 |
Phase voltmeter | 1PC |
Current clamp | 2PCS |
USB communication line | 1PC |
Monitoring software (CD-ROM) | 1PC |
Instrument box | 1PC |
Test line | 4PCS(Red、black each 2) |
6V Ni-MH rechargeable battery(internal) | 1PC |
Charger | 1PC |
Manual, certificate | 1SET |