Function: | Simultaneous measurement of three-phase AC voltage, current, phase, frequency, phase sequence, active power, power factor, etc. |
Voltage range: | AC 0.00V~600V |
Current range: | AC 0.0mA~1000A |
Phase range: | 0.0°~360.0° |
Active power: | 0.0W~600kW |
Power factor: | -1~+1 |
Jaw size: | 50mm |
Function | Measure three-phase AC voltage, current, voltage phase, current phase, voltage and current phase, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum,judging the transformer wiring group, inductive, capacitive circuit, test secondary circuit and busbar protection system,read out the phase relationship between the CTs of the differential protection groups, check the correctness of the wiring of the watt-hour meter, repair the line equipment, etc. | ||
Power | 3.7V lithium rechargeable battery | ||
Power consumption | Max 50mA | ||
Display mode | LCD color display,72×55mm | ||
Instrument size | W/H/T:187*119*48mm | ||
Voltage | AC 0.00V~600V | :0.01V | ±0.5FS |
Current | AC 0.0mA~1000A | Resolution:0.1mA | ±0.5FS |
Phase | 0.0°~360° | Resolution:0.1° | ±1° |
Frequency | 45Hz~65Hz | Resolution:0.01Hz | ±0.5Hz |
Active power | 0.0W~600kW | Resolution:0.1W | ±(3%rdg+3dgt) |
Reactive power | 0.0VAR~600kVAR | Resolution:0.1VAR | ±(3%rdg+3dgt) |
Apparent power | 0.0VA~600kVA | Resolution:0.1VA | ±(3%rdg+3dgt) |
Power factor | -1~+1 | :0.001 | ±0.03 |
Current vector sum | 0mA~3000A | Resolution:1mA | |
Phase sequence |
Normal phase:U1、U2、U3 or I1、I2、I3 cursor blinks from left to right Opposition:U1、U2、U3 or I1、I2、I3 cursor blinks from right to left |
||
Detection rate | About 2 second/time | ||
Data hold | Press HOLD key to hold data during test, "HOLD" symbol display | ||
Data storage | 400 groups | ||
Silicone protective sleeve | Have | ||
USB interface | USB interface, uploading data to a computer for analysis of management data | ||
Automatic shut-down | About 15 minutes after power on, the meter will automatically shut down to reduce battery consumption | ||
Backlight function | Yes, suitable for dark places and night use | ||
Voltage detection | When the battery voltage is lower than 3.2V, the battery voltage is low and the symbol indicates, prompting timely charging | ||
Instrument weight | Hose:380g(including battery) | ||
Large diameter current clamp:440g×3 | |||
Test line:190g | |||
Voltage test line length | 1.5m | ||
Current clamp line length | 2m | ||
Working temperature and humidity | -10℃~40℃;below 80%Rh | ||
Storage temperature and humidity | -10℃~60℃;below 70%Rh | ||
Input impedence | Test voltage input impedance is:1MΩ | ||
Pressure resistance | The withstand voltage of 1000V/50Hz sine wave AC voltage between the instrument circuit and the housing lasts 1 minute | ||
Insulation | Between instrument line and housing≥100MΩ | ||
Structure | Housing insulation | ||
Suitable for safety regulations | IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,pollution level 2 |
Phase voltmeter | 1PC |
Current clamp | 3PCS |
USB communication line | 1PC |
Monitoring software (CD-ROM) | 1PC |
Instrument box | 1PC |
3.7V lithium rechargeable battery (Internal) | 1PC |
Test line | 4PCS(yellow, green, red, black each one) |
Charger | 1PC |
Manual, certificate | 1SET |